Versions Compared
Key
- This line was added.
- This line was removed.
- Formatting was changed.
...
Field descriptions:
Read the source if you need to know more of the technical aspects of these fields.
- Tau, Beta (3 values), and Complete are the only fields used by SmoothQuick.
- DampMin, DampRate, DampMax affect the control damping. Decrease damping to make your aircraft response more rapidly.
- NoiseMin, NoiseRate, NoiseMax affect control sensitivity. Increasing noise (sensitivity) will make your aircraft respond more rapidly, but will cause twitches due to noise.
- Damp and Noise put together form the dual virtual slider SmoothQuick
- CalculateYaw can be False,TrueLimitToRatio,TrueIgnoreLimit default is TrueLimitToRatio
- YawToRollPitchPIDRatioMin is enabled with CalculateYaw default is 1.0
- YawToRollPitchPIDRatioMax is enabled with CalculateYaw default is 2.5
- DestinationPidBank default is 2
- TuningDuration is 60 seconds
- SmoothQuickSource default is 25
- DisableSanityChecks disables certain checks that stop the PIDs from being written default is false
- Complete is set true after a successful AutoTune run. It must be true for PIDs to be written to DestinationPidBank
, in real time, while you are flying the tuned PID bank